Corrected pin count on ASIC 108->84.  TerryB 10:49, 7 Jan 2016 (PST)
Corrected pin count on ASIC 108->84.  TerryB 10:49, 7 Jan 2016 (PST)
== WPC 10 Opto Board Problems ==
"Sometimes the switch edge test can show one or multiple opto switches flickering open and closed." 
I am looking for clarification on this statement.  Will it only affect other optos or will it also affect physical switches which would only be apparent if they are closed?
I am guessing from that statement that this would affect all switches on either the columns and/or rows that are connected to this 10 Opto Board, but I am looking for confirmation. 
For example, if U2 were affected, that could affect two columns (labeled as columns 1 & 2 in the schematic but can be any two columns in the switch matrix). 
It might also affect rows 5, 6 & 7 as U2 is connected to those two columns and three rows.  U1 would affect rows 1 - 4.  U3 would affect rows 1 - 3.

Revision as of 09:46, 19 September 2026

We should push game-specific comments into the game page. Having them all up front is messy. We can always create compendium pages later.--Mr 04:04, 7 May 2011 (BST)

Hey Martin...I agree...After the other reorganizing I did...I ran out of energy. BTW, I made a new page called "WPC DMD Controller Board"...just to be a bit more consistent with other namings. I copied your crack at it into that page. I don't know how to delete old pages. --Chris Hibler 04:49, 7 May 2011 (BST)

OK Martin, et.al....moved game specific issues and fixes to a subpage for now...Eventually, these should be moved to the game specific page.
--Chris Hibler 04:58, 7 May 2011 (BST)

Moved all game specific issues to the game's subpage... --Chris Hibler 03:58, 9 May 2011 (BST)

OK, I am going to push a few other repairs into their appropriate pages. --Mr 07:16, 21 May 2011 (BST)

Dielectric grease is not conductive

Corrected pin count on ASIC 108->84. TerryB 10:49, 7 Jan 2016 (PST)

WPC 10 Opto Board Problems

"Sometimes the switch edge test can show one or multiple opto switches flickering open and closed."

I am looking for clarification on this statement. Will it only affect other optos or will it also affect physical switches which would only be apparent if they are closed?

I am guessing from that statement that this would affect all switches on either the columns and/or rows that are connected to this 10 Opto Board, but I am looking for confirmation.

For example, if U2 were affected, that could affect two columns (labeled as columns 1 & 2 in the schematic but can be any two columns in the switch matrix). It might also affect rows 5, 6 & 7 as U2 is connected to those two columns and three rows. U1 would affect rows 1 - 4. U3 would affect rows 1 - 3.